About this page. This is the running deep dive: the scans, measurements and research behind John’s decisions, updated as we learn more. It’s written by John’s Claude Fable Agent over the course of the last 10 months and counting. While Claude isn’t a doctor or a radiologist, and the care team makes the medical calls, the work has held up!! The tumor measurements match the official radiology report within 1 to 2 mm, Dr. Yates’s own measurement of the growth (about 8 mm) is in line with ours, and none of John’s doctors has disputed any of the reads or research.
Last updated October 15, 2026.
The short version (October 3, 2026 MRI)
What the radiologist’s report says (October 3 scan):
- The tumor measures 33 × 28 × 28 mm, about 3.3 cm at its longest.
- It presses on the right side of the brainstem and has pushed it slightly to the left.
- The fluid spaces in the brain are a normal size. No fluid buildup (hydrocephalus), no bleeding and no stroke.
- The inner ears look normal on both sides.
How it compares with December. The radiologist didn’t have John’s earlier scans, so the report says nothing about growth. John and I compared the October images with his December 2025 MRI ourselves, using measuring software. These are our measurements, not a radiologist’s: the tumor was about 2 to 2.5 cm in December and is now about three times the volume. Most of these tumors grow about 1 mm a year, so this is fast. The growth has been inward, toward the brain, not out into the ear. John is working on getting an official comparison from his doctors.
The numb cheek. The nerve that carries feeling from the face appears to run into the top of the tumor. That probably explains the numbness John has had since the summer, though only his doctors can say for sure.
What it means. At this size, and touching the brainstem, the tumor needs treatment rather than watching. The plan is now set: surgery on November 9 (see the October 15 visit notes).
The full analysis of the October 2026 MRI
Written October 4 and 5, 2026 for John to take to his October 6 consult, so “you” means John. Personal identifiers and file references removed. The “Time-sensitive” box was John’s to-do list for that week.
What this is. A measured, non-radiologist look at your new MRI (October 3, 2026, Dupont Hospital) set against the December 8, 2025 scan. It uses the same measuring rules as the September 27 review, so the numbers are comparable. Every finding carries a confidence level. Where I couldn’t tell, I say so. Two further passes checked it: one re-measured everything independently, and one tried to break each finding (section 10). The official radiology report arrived on October 5 and is compared with this review just below the box.
Update, October 5: the official radiology report
The written report for the October 3 scan arrived on October 5. The radiologist’s read is the authoritative one. Here is how it lines up with this review.
| Item | 10/6 Radiologist Report | My AI Review | How they compare |
|---|---|---|---|
| Size | 33 × 28 × 28 mm (long axis × short axis × height) | 33 to 35 × 28 × 28 to 30 mm measured the same way; about 31 mm outside the ear canal | Agree within 1 to 2 mm |
| Brainstem | Mass effect on the right brachium pontis and right cerebellum; pons displaced left of center | Right half of the brainstem flattened; tumor edge within about 2 mm of the midline | Agree |
| 4th ventricle | Partially effaced | Shifted about 2 mm left; cross-section about the same as in December | Agree on the displacement. The radiologist’s wording is stronger and takes precedence |
| Ventricles | No hydrocephalus; normal size for age | 40 to 50% more fluid than in December; width index under the cut-off for “enlarged” | Not in conflict. Normal in size now, and on my measurement larger than ten months ago. The radiologist had no earlier scan, so could not judge change |
| Growth since December | Not assessed (“Comparison: None”) | About three times the volume; long axis about 25 mm → 33 to 35 mm | Only this review compares the two dates |
| Inside of the tumor | Heterogeneous before dye, on T2 and after dye; compatible with vestibular schwannoma | More uneven than in December | Agree |
| Bleeding, stroke | None | No blood signal | Agree |
| Inner ear | Normal in appearance on both sides | Right inner-ear fluid dimmer than the left | Not confirmed by the official read |
| Trigeminal nerve, Koos grade, cerebellar tonsils | Not mentioned | Sections 4 and 6 | No official statement either way |
What this changes:
- The size and the brainstem displacement are now official.
- “No hydrocephalus” is the authoritative statement on the fluid spaces. I had called the ventricle change a possible early sign of hydrocephalus. The better wording is: normal in size, apparently larger than in December, and worth a direct comparison by a radiologist who has both scans.
- Growth is the gap. The official report is silent on it because it had nothing to compare with. That is the fact to carry to every office.
- Inner ear. Treat the dimmer-fluid measurement as a subtle finding that the official read does not confirm.
- If you can get the written report for the December 2025 scan, the two official sizes can be put side by side.
1. Plain-language summary
- The tumor has grown a lot in ten months. (High confidence.) – Volume: about 12 mL (11 to 13 across separate measurements), up from about 3.6 mL in December 2025. That is a little over three times the volume. – Largest diameter outside the ear canal: about 31 mm (30 to 32), up from about 20 mm. The official report, which includes the part in the canal, gives 33 × 28 × 28 mm. – Height: about 30 mm, up from about 20 mm. It now reaches about 15 mm above and 15 mm below the ear canal. – This is far faster than these tumors usually grow (about 1 mm a year on average).
- The growth is toward the brain, not into the ear. The tip inside the ear canal is in the same place, within about 1 mm. The tumor has expanded inward (about 8 mm), backward (about 10 mm), up (about 5 mm) and down (about 5 to 6 mm). (High confidence.)
- It now deforms the brainstem. In December it touched the brainstem. Now its inner edge has moved about 9 mm inward and reaches to within about 2 mm of the head’s midline. The right half of the brainstem is flattened, and the 4th ventricle (a fluid space behind the brainstem) has shifted about 2 mm to the left. The official report confirms that the pons is displaced and the 4th ventricle partly effaced. That matches Koos grade IV. In September I couldn’t choose between III and IV. (High confidence on the deformation; the grade itself is the radiologist’s call.)
- The fluid spaces hold more fluid than in December, but are normal in size. The side ventricles hold about 40 to 50% more fluid, and the third ventricle is about 1 to 3 mm wider. The official report says there is no hydrocephalus and the ventricles are normal in size for your age. The radiologist had no earlier scan, so the change since December is this review’s measurement alone. (High confidence that they are larger than in December; what it means is for your team.)
- Trigeminal nerve (feeling in the face). The new scan is good enough to follow the nerve. It runs back from its pocket in the skull base (Meckel’s cave) into the top-front surface of the tumor. From there to the brainstem, about the last 7 to 9 mm, I can’t separate nerve from tumor. At that level the right side of the brainstem has been pushed about 7 to 8 mm out of its normal position, and the tumor rises about 6 mm above the nerve. Any of these could explain the numbness getting worse. I saw no tumor in Meckel’s cave. (Medium confidence.)
- The tumor looks more uneven inside. In December it took up dye evenly. Now a few percent of the inside (roughly 3 to 10%, depending on the rule) takes up dye weakly or slowly. I saw no blood signal that I can recognize. Whether this is cystic or degenerative change is for the radiologist. (Low-medium confidence on what the pattern means.)
- Inner ear. The fluid in the right balance chamber (vestibule) is clearly dimmer than on the left, and more so than in December. The right cochlea is dimmer on the fine-detail scan only. Both are still visible as fluid-filled spaces. The official report calls the inner ear structures normal on both sides, so treat the dimming as unconfirmed. The hearing nerve can’t be seen on the right because tumor fills the canal. (Low-medium confidence.)
- The open question from September is likely explained. The September review could not tell whether the upper-back part had grown between September and December 2025. I found that your head moved about 7 degrees during the December exam, between the scans before and after the dye. The earlier method did not correct for that, and it explains why the mismatch showed up at that one edge. It does not rule out about 1 mm of growth all round in those three months. (Medium confidence; the September scan was not available, so I could not re-test it directly.)
- For Tuesday: the size, the brainstem pressure and the ventricle change all bear on whether Gamma Knife alone is still suitable. The question list is in the last section.
2. What I looked at and how the scans were compared
| December 8, 2025 | October 3, 2026 | |
|---|---|---|
| Study | MRI brain/IACs without and with contrast (Clariscan, 16 mL) | MRI brain without and with contrast (ProHance, 16 mL) |
| Where | Choice Imaging | Dupont Hospital |
| Scanner | FUJIFILM Oasis Velocity, 1.16 T open-bore | Siemens MAGNETOM Aera, 1.5 T |
| Fine-detail fluid scan | 3D T2, 0.4 mm in-plane, 1 mm slices; stops below the top of the tumor | 3D CISS, 0.35 mm in-plane, 0.7 mm slices; covers the whole tumor and the trigeminal level |
| Thin dye scans | T1 before and after dye, 3 mm slices, two directions | T1 before and after dye, 2 mm slices; after-dye coronal 3 mm; plus a 1 mm whole-brain after-dye scan |
| Written radiology report | (not on hand) | Received October 5 |
The September 12, 2025 scan was not available for this review, so this review compares October 2026 with December 2025. For September, I rely on what the 09-27 review measured.
Steps:
- Checked that the download is complete: all 936 images match the disc’s own index.
- Outlined the enhancing tumor on both dates with the same rule as on 09-27 (after-dye image minus before-dye image).
- Lined the October scan up with December on the skull base, leaving the tumor out so that its growth can’t pull the alignment.
- Tested the alignment several ways (section 12). At the tumor, independent routes agree to within 0.5 mm. The two scanners agree on scale: the two inner ears are 66.2 mm apart on both dates.
- Measured both dates in one common frame with the same rules.
- Found and corrected for head movement between series inside each exam (section 9).
- Had a reviewer re-measure everything with separate code, and a challenger try to break each finding (section 10).
3. Size and growth

| Measurement | Dec 8, 2025 | Oct 3, 2026 | Change |
|---|---|---|---|
| Volume | about 3.6 mL (3.4–3.9) | about 12 mL (11–13) | a little over ×3 |
| The same by reader: lead / reviewer / challenger | 3.8 / 3.4–3.6 / 3.5–3.7 mL | 12.5 / 11.5–12.1 / 11.2–12.4 mL | ×3.1 to ×3.4 |
| Largest diameter outside the canal: lead / reviewer / challenger | 20.4 / 20.6 / 20.5 mm | 31.6 / 30.3–30.9 / 31.7 mm | +10 to 11 mm |
| At that level: along the bone face × straight out from it | 19.2 × 19.4 mm | 29.9 × 28.2 mm | |
| Height (top to bottom) | 20.0 mm | 30.5 mm | +10.5 mm |
| Position relative to the ear canal | 9.9 mm below to 9.6 mm above | 15.4 mm below to 14.6 mm above | +5 up, +5.5 down |
| Longest dimension including the canal part | 24.9 mm | 34.7 mm | +10 mm |
| Part inside the ear canal | about 0.1 mL | about 0.1 mL; tip in the same place within about 1 mm | none |
| Official report: long axis × short axis × height | not on hand | 33 × 28 × 28 mm | |
| The same three measures on my outlines | about 25 × 19 × 20 mm | about 34 × 28 × 30 mm | about +9, +9, +10 mm |
- Pace. 299 days separate the scans. The change is equivalent to the volume doubling about every 6 months, or the largest diameter growing about 12 to 13 mm a year. Two scans can’t show whether the growth was steady or came in a step. The usual figure for tumors that grow is about 1 mm a year (Paldor 2016).
- Direction. The December outline lies almost entirely (98%) inside the October outline. The edge moved inward toward the brainstem by about 8 mm, backward by about 10 mm, up by about 5 mm and down by about 5 to 6 mm. The front edge moved 1 mm or less. Bone holds the front and the canal.
- Not a dye effect. The same amount of dye was given on both dates. On the fluid-sensitive scans, which use no dye, the tumor’s edge sits within about half a millimetre of the dye outline on both dates.
- A small caveat. About 0.2 mL at the lower front of the October outline may be a vein or the lining rather than tumor. It is under 2% of the volume.
- December re-measured. With the head-movement correction, my rule gives 3.8 mL and 20.4 mm. The 09-27 figures were 3.7 mL and about 20 mm, so the correction barely changes them.
- Earlier pace. Between September and December 2025 the 09-27 review found about 1 mm of edge shift, which it judged within error. So the earlier pair gave no sign of the present pace. Your numbness progressed between June and August 2026.
(High confidence that the growth is real and large. Each volume carries roughly ±10%.)
Why I trust it: the two scans line up on bone to better than 1 mm (0.3 to 0.5 mm at the inner ears), the scanners agree on scale, three separate readers with separate code get the same sizes, and the change is 5 to 10 times larger than any measurement error found.
4. Brainstem and 4th ventricle

- December 2025. The tumor touched the right side of the brainstem. Its inner edge was about 10 to 11 mm from the head’s midline. The 4th ventricle sat on or just left of the midline (0 to 2.5 mm, depending on which of three midline estimates is used). Some indentation of the brainstem may already have been present; the 09-27 review could not rule it out.
- October 2026.
- The inner edge is within about 2 mm of the midline (0.5 to 2 mm across three midline estimates). On every estimate it has moved about 9 mm inward.
- The right half of the brainstem is flattened. Measured across the belly of the pons, the right half was 10 to 15 mm wide in December and is 1 to 5 mm wide now.
- The 4th ventricle sits 2 to 4 mm left of the midline, more at its lower end. On every estimate it has shifted about 2 mm to the left since December.
- The 4th ventricle is still open: its cross-section is about the same size as in December.
- Official report. “Displacing the pons left of center and partially effacing the 4th ventricle.” That confirms the displacement. Its wording on the 4th ventricle is stronger than my measurement, and it takes precedence.
- Koos grade. Grade IV means a large tumor that displaces the brainstem. That is what the images show. (High confidence on the deformation; ask for the official grade.)
- Swelling in the brain next to the tumor. None that can be measured: the brain beside the tumor is no brighter than the mirror-image spot on the left, on either date. (Medium confidence.)
- Cerebellar tonsils. On the side-view scans the lowest part of the cerebellum ends several millimetres above the opening at the base of the skull on both dates, with fluid still around it. A change of 1 to 3 mm between the dates could not be measured. (Low-medium confidence; ask the radiologist to confirm.)
5. Fluid spaces (ventricles)

| Measurement, same slices on both dates | Dec 2025 | Oct 2026 | Change |
|---|---|---|---|
| Side (lateral) ventricles, upper part, T2 scans | 16.4 mL | 24.1 mL | +47% |
| The same, on the 5 mm after-dye T1 scans | 14.3 mL | 21.8 mL | +52% |
| Challenger’s re-cut: third + side ventricles, T1 pair | 22.3 mL | 33.6 mL | +50% (+43 to +58%) |
| Challenger’s re-cut: third + side ventricles, T2 pair | 27.7 mL | 38.1 mL | +38% (+32 to +39%) |
| Reviewer: upper part, T1 pair | 13.6 mL | 20.5 mL | +51% |
| Reviewer: upper part, T2 pair | 15.5 mL | 22.4 mL | +44% |
| Reviewer: upper part, FLAIR pair | 14.2 mL | 19.8 mL | +40% |
| Third ventricle width | 6.5 to 9.2 mm | 7.9 to 10.6 mm | +1 to 2.5 mm |
| Widest span across the front horns | 29 to 31 mm | 31 to 33 mm | about 2 mm |
| Evans index (inner skull width 134 mm) | about 0.22 to 0.23 | about 0.23 to 0.24 | below the usual 0.30 cut-off |
- Official report: “No hydrocephalus; normal size for age.” That is the authoritative statement of where things stand now. It agrees with the width index in the table.
- The side ventricles and the third ventricle are clearly larger than ten months ago: about 40 to 50% more fluid. Seven measurements on three kinds of scan, by three separate methods, all point the same way. Shifting the alignment by 2 mm or 1.5 degrees on purpose still leaves more than 40%. (High confidence that they are larger; medium on the exact percentage.)
- The temporal horns (the lowest part of the side ventricles) also look larger: about 1 to 1.5 mm wide in December and 2 to 3 mm now on the T2 scans. (Low-medium confidence.)
- The front horns have not widened much, so the simple width index is still under the usual cut-off for “enlarged”. So the ventricles are normal in size and, on these measurements, larger than they were. The radiologist had no earlier scan, so that change is this review’s finding alone. Ask for the two scans to be compared directly.
- There is no bright halo around the ventricles on FLAIR, by measurement, on either date. Such a halo would point to pressure building quickly.
- Hydrocephalus occurs with these tumors: 53 of 400 patients (13%) in one large surgical series, and removing the tumor resolved it in most of them (Gerganov 2011).
6. Trigeminal nerve (feeling in the face)

Your numbness is a trigeminal symptom. In 2025 the nerve could not be found on the scans. The October CISS scan is sharper and covers the right level.
- Left (normal) side. The nerve shows as a striped grey band about 3 mm wide with fluid on both sides, running about 15 mm from the brainstem forward to Meckel’s cave. (Medium-high confidence.)
- Right side. A band of the same width and texture leaves Meckel’s cave and runs back. It stays grey on the dye scans, where a vein would turn bright. It meets the top-front surface of the tumor, and from there back I can’t see fluid between the two. All three readers saw the same thing. (Medium to medium-low confidence. Telling a nerve from a neighbouring blood vessel or membrane is the weakest part of this reading.)
- The last stretch. From that meeting point to the brainstem, about 7 to 9 mm, I can’t separate nerve from tumor, and I can’t see where the nerve enters the brainstem.
- The brainstem has moved. On the left, brain begins about 2 to 2.5 mm inward of the nerve’s entry point. Inward of the mirror-image spot on the right there is about 7 mm of fluid first, and brain begins 9 to 10 mm in. So at this level the right side of the brainstem is about 7 to 8 mm out of its normal position.
- How close the tumor has come. Measured against where the nerve would normally run (the mirror image of the left nerve), the tumor’s surface is 1 to 2 mm closer than in December. That is within the error of the method, and the brainstem has moved, so treat it as a rough guide only.
- Height. The tumor’s top is now about 6 mm (±2) above the nerve’s level. In December it was about level with it.
- Meckel’s cave. No tumor there. On the dye scans both caves are dark fluid pockets with the same slight dye uptake, and the tumor’s nearest surface is 15 to 18 mm away. The CISS scan covers only the back few millimetres of the caves. (Medium confidence.)
- Trigeminal symptoms have been linked to brainstem or nerve compression (Grigoryan 2021).
7. Ear canal, inner ear, facial nerve and lower nerves

- Ear canal. Tumor fills it, as before. On the dye images the tip of the enhancing tumor is in the same place on both dates, within about 1 mm. (Medium-high confidence.)
- Far end of the canal. The small pocket beyond the tumor’s tip still does not enhance. In December it was fluid-bright. On the October CISS it is dim, like the vestibule. That may be the same dimmed fluid; tissue can’t be ruled out. (Low confidence.)
- Inner ear fluid, right vs left.
- Vestibule. Dimmer on the right on two kinds of scan: about 57% dimmer on the CISS and about 30 to 35% on ordinary T2. In December it was about 15% dimmer on ordinary T2. (Medium confidence that it is dimmer and that this has increased.)
- Cochlea. About 30% dimmer on the CISS only (±15%). On ordinary T2 it matches the left on both dates. (Low-medium confidence.)
- The spiral of the cochlea and the vestibule are still visible as fluid-filled spaces.
- Official report: the inner ear structures are “normal in appearance bilaterally”. So the dimming is a subtle measurement that the official read does not confirm.
- This matters for the cochlear-implant question in the 09-28 plan. Dimmer fluid is usually put down to protein in the fluid rather than scarring, but that is a question for the neurotologist.
- Hearing nerve. Not visible on the right. On the left the nerves show as dark lines in a fluid-filled canal.
- Facial nerve. Not visible as a separate structure, as expected at this size (see the 09-27 review, section 3).
- Lower nerves (swallowing, voice). The bottom of the tumor is now about 15 mm below the ear canal. It was about 10 mm. That brings it closer to the nerves that leave the skull lower down. I did not examine them in detail.
8. What the tumor looks like inside
| Dec 2025 | Oct 2026 | |
|---|---|---|
| Share of the inside that takes up dye weakly | 0.1 to 0.5% | 3 to 11%, depending on the cut-off (about 0.4 to 0.6 mL by the two tighter rules) |
| The same with October blurred to December’s sharpness | 0.5% | 4 to 5% |
| Brightness on T2, where 0 = brain and 1 = fluid (rough; depends on the reference) | 0.31, or 0.74 | 0.52, or 0.84 |
| Diffusion value (ADC) relative to the pons | 1.74 | 1.74 |
| Bright spots before dye (would suggest recent bleeding) | none | none |
- The inside is more uneven than in December, and the difference survives blurring the sharper October scan down to December’s level. (Medium confidence.)
- The weak areas are bright on T2 and partly fill in on the scan taken about ten minutes later. October’s first dye scan probably started sooner after the injection than December’s, so part of the unevenness may be timing.
- No blood signal on any series here. Neither exam included a blood-sensitive scan, so small old bleeds can’t be excluded.
- There is no single large cyst. Whether this is cystic or degenerative change is for the radiologist. It matters for planning: in a pooled analysis, facial-nerve results after surgery were worse for cystic tumors than for solid ones (Thakur 2012).
9. The September question, and head movement inside the December exam
- What 09-27 left open. On the September 2025 scan, a thin band of fluid sat inside the area that the December outline covered, at the upper, back, outer edge. It could have been a few millimetres of growth, or an artefact.
- What I found. During the December exam your head turned about 7 degrees in total (about 5 degrees about each of two axes) between the scans taken before the dye and those taken after. At the tumor that amounts to 2 to 3 mm. It is visible by eye when the two series are overlaid. The head also shifted by smaller amounts between other series that day. The October exam shows only 1 to 2 mm of drift.
- Why it matters. The December outline was drawn on after-dye images. On 09-27 it was laid onto before-dye T2 images as if the head had not moved. That placed the outline about 2 mm too far up, back and outward.
- A same-day test. On December’s own T2 scan, where growth is impossible, the outline laid the old way is lopsided by about 2.6 mm: it reaches the fluid at the back-outer edge and stops short at the front-inner edge. With the correction it sits evenly all round.
- Conclusion. The head movement explains why the mismatch appeared at that one edge. It does not rule out about 1 mm of growth all round between September and December, which is what 09-27 measured and judged within error. Given what followed, that may have been real. (Medium confidence.) The September images are needed to close this.
- Effect on the December numbers. Small. Volume moves from 3.7 to 3.8 mL.
10. Independent cross-check (Two additional Fable Agents)
Two further passes follow the lead read. Both are other Claude instances, not radiologists. Each wrote its own image loader and measuring code.
Challenger. Asked to argue the strongest alternative for every finding and test it. It wrote its own image loader and alignment code.
| Finding in the draft | Challenger’s result | Where that leaves it |
|---|---|---|
| Growth: 3.8 → 12.5–13 mL; 20 → 31.6 mm | Re-measured each scan alone with a different rule: 3.5–3.7 → 11.2–12.4 mL; 20.5 → 31.7 mm. T2 edge matches the dye outline. Scale within about 1% | Survives. Now stated as “about 12 mL (11–13)”; scale wording loosened from 0.15% |
| Direction of growth; canal tip unchanged | Same directions and sizes with its own outlines and alignment | Survives. “Within 0.5 mm” loosened to “about 1 mm” |
| Brainstem deformed; 4th ventricle shifted | Fitted a midline at the skull base itself: my midline was about 0.6 mm off. Tumor edge 10.9 → 2.1 mm; 4th ventricle 0.1–0.3 → 1.9–2.1 mm | Survives. Both midlines now quoted |
| Ventricles larger: +47% / +52% | Re-cut October into December’s exact slices: +50% (T1 pair), +38% (T2 pair) | Survives. Now “about 40 to 50%” |
| Right trigeminal nerve can be followed to the tumor | Agreed after checking it against the dye scans | Survives (medium) |
| Tumor “within 1 to 2 mm of where the nerve joins the brainstem” | The mirror-image entry point is no longer on the brainstem: the brainstem there has moved about 7 mm | Did not survive. Removed from the summary, section 6 and Figure 4, and replaced with what can be seen |
| No tumor in Meckel’s cave | The CISS covers only the back of the caves; confirmed on the dye scans instead | Survives on different evidence |
| Inside: “3.4%”, “0.31 → 0.52”, “cystic” | Real, but rule-dependent, and partly a timing effect | Weakened. Now “3 to 7%”, and “cystic” left to the radiologist |
| Inner ear: cochlea and vestibule dimmer | Vestibule solid on two scan types; cochlea on CISS only, ±15% | Weakened for the cochlea |
| Head movement explains the September question | Movement confirmed. It explains the location of the mismatch, not that there was no growth | Weakened from “most likely an artefact” |
| Time-sensitive box | All three items survive; no tonsil descent, no bright rim, no brain swelling | Proportionate. The reassuring absences were added to the box |
I checked the one finding that did not survive myself and agree with the challenger: inward of the mirror-image point on the right there is about 7 mm of fluid, and brain begins about 9 mm in (2.5 to 3 mm on the left).
Reviewer. Asked to redo the key measurements independently. It measured against the first draft before the challenger’s results existed. Its first run was cut off by a usage limit and resumed; a few checks, marked “added later” in its report, were run after it had read the revised draft.
| Finding | Lead | Reviewer’s own value | Verdict |
|---|---|---|---|
| Tumor volume, Dec 2025 | 3.8 mL | 3.4–3.6 mL (3.8 on 5 mm slices) | Confirmed |
| Tumor volume, Oct 2026 | 12.5 mL | 11.5–12.1 mL on four series | Confirmed |
| Volume ratio | ×3.3 | ×3.3–3.4 | Confirmed |
| Largest diameter outside the canal | 20.4 → 31.6 mm | 20.6 → 30.3–30.9 mm | Adjusted to “about 31 mm (30–32)” |
| Direction of growth | in 8, back 10, up 5, down 5–6 | in 8.1, back 10.1, up 5.7, down 6.0 mm | Confirmed |
| Alignment of the two scans | under 1 mm on bone | median 0.64 mm on bone blocks; 0.3–0.5 mm at inner-ear landmarks | Confirmed |
| Scale between scanners | within about 1% | cochlea to cochlea 66.18 vs 66.23 mm | Confirmed, tighter |
| Head movement inside the Dec exam | about 7° | 7.0° (2.2 mm at the tumor) | Confirmed |
| Tumor edge to midline | 10.2 → 1.5 mm | 9.5–10.9 → 0.5–2.0 mm over three midlines | Confirmed; now quoted as ranges |
| 4th ventricle | on the midline → 2.7–2.9 mm left | by its own midline 1.7–2.7 → 4.1–4.2 mm left; shift 1.5–2.5 mm | Shift confirmed; “on the midline in December” reworded |
| Brainstem out of mirror position at the nerve’s level | about 7 mm | 7.7 mm | Confirmed |
| Side ventricles, upper part | +47% (T2), +52% (T1) | +44% (T2), +51% (T1), +40% (FLAIR) | Confirmed |
| Third ventricle | +1 to 3 mm | +0.5 to 3 mm by scan type | Confirmed; now “+1 to 2.5 mm” |
| Evans index | 0.22 → 0.23 | 0.23 → 0.24, with skull width 134 mm on both dates | Corrected: my script’s skull width differed between dates |
| Right trigeminal nerve meets the tumor | medium confidence | same reading; medium-low | Confirmed |
| Mirror-line distance to the nerve’s path | 1–3 mm closer | about 1 mm closer, inside the error | Weakened to “1 to 2 mm, within error” |
| Inner ear: vestibule and cochlea | 57% and about 30% dimmer on CISS | 57% and 23–27% | Confirmed |
| Inside of the tumor | 3–7% weakly enhancing | 3–11% by cut-off | Confirmed in kind; range widened |
| Time-sensitive box | this week, not tonight | all three items and the reassuring absences hold | Proportionate |
The reviewer also pointed out that the midline is only known to about ±1 mm, so every distance from it is now given as a range. It did not test the diffusion figure, the late filling-in of the weak areas, the far-end pocket of the canal, or the literature.
11. Limits
- None of the three passes is a radiologist. The outlines and landmarks are careful but amateur, and the cross-checks share that limit.
- The official report had no earlier scan to compare with. It confirms the size and the brainstem displacement and is silent on growth.
- Two different scanners. This affects brightness comparisons (the inside of the tumor, the inner-ear fluid) much more than sizes and positions.
- September 2025 is missing here. The three-point trend rests on the 09-27 review for September.
- Nerve identification. Following the right trigeminal nerve is a best judgement. A neuroradiologist with the full scan can do better.
- The midline is only known to about ±1 mm, so distances from it are given as ranges.
- Tonsils and temporal horns were judged crudely.
- Not assessed: blood vessels, the lower cranial nerves in detail, and the rest of the brain for unrelated findings.
12. Method details
- Tools. Python (pydicom, numpy, scipy, Pillow), run locally on John’s own computer.
- Outline rule (unchanged from 09-27). After-dye minus scaled before-dye T1 on a 0.5 mm grid. Core at 65% or more of the tumor’s own enhancement, grown up to 2 mm into voxels at 45% or more, holes filled. New: the before-dye series is registered to the after-dye series first. December uses axial and coronal pairs averaged. October uses the axial pair and the coronal after-dye series with the axial before-dye series.
- Volumes by variant (my rule). December: axial 3.74, coronal 3.93, fused 3.78 mL (3.4–4.1 across settings). October: axial 11.92, coronal 12.87, fused 12.48 mL (10.5–13.3 across settings); 13.00 mL after adding low-enhancing pockets (2 mm closing).
- Alignment of October to December. Rigid, 6 parameters, on the thin after-dye T1 series over the posterior fossa, with a sphere around the tumor excluded. Correlation 0.911.
- Scale. Letting scale float gave 1.0015 on that fit. The challenger’s fits gave 1.000 to 1.006. The reviewer’s nine landmark pairs gave 0.9999 ± 0.0004. Up-down scale is the least well pinned down, because slices are thick.
- Independent alignment routes. October CISS to December 3D T2 using only boxes around the two inner ears (bone-locked), chained through each exam’s own T1-to-T2 alignment: 0.3 to 0.5 mm from the main route at the tumor. The challenger’s whole-head alignment: 0.5 mm from it.
- Midline. Three estimates. Mine: left-right mirror symmetry of the upper head, separately on each date (the two agree to within 0.5 mm at the tumor’s level). The challenger’s: mirror fits at the skull base on four series (agree within ±0.2 mm), about 0.6 mm to the left of mine at the 4th ventricle. The reviewer’s: the plane midway between the two inner ears, about 1 mm to the right of mine at the brainstem.
- Outline front edge. The fused outline’s front edge sits 1.5 to 2 mm further forward than the thin axial outline on both dates, because the coronal slices are 3 mm thick. That affects only distances measured from the front edge.
- Evans index. Front-horn span divided by the inner skull width. The skull width (134 mm on both dates) is the reviewer’s; my own script gave different widths on the two dates and was dropped.
- Head movement inside an exam. Each series was registered to its exam’s reference series. December: 4.8°, 2.4° and 4.5° about the three axes between the before-dye and after-dye blocks (6.9° in total). October: translations of 1 to 2 mm, rotations under 1.5°.
- Ventricles. Mine: fluid fraction per voxel, (signal − brain) / (fluid − brain), summed over the connected ventricle region in a fixed slab above the foramina of Monro, on a common 1 mm grid; October T2 averaged to 5 mm to match December. The challenger’s: October re-cut into December’s slice positions and thickness, one shared region including the third ventricle.
- 4th ventricle. Centroid of the fluid region at matched planes, relative to the midline plane. December was measured on two series.
- Trigeminal. Left nerve course read from the CISS and mirrored across the midline plane. Brain edge found by walking inward from the entry point and its mirror image.
- Inner-ear fluid. Mean signal in 1.2 mm spheres centred on the cochlea and vestibule, re-centred per series, relative to cistern fluid. Control regions (brain beside each ear, fluid at the back of Meckel’s cave) by the challenger.
13. Sources
Verified 2026-10-04 (PubMed):
- Goldbrunner R, Neuro Oncol 2020;22:31 (EANO guideline). https://pubmed.ncbi.nlm.nih.gov/31504802/
- Gerganov VM, J Neurosurg 2011;114:1209. https://pubmed.ncbi.nlm.nih.gov/21142748/
- Yang HC, J Neurosurg 2011;114:801. https://pubmed.ncbi.nlm.nih.gov/20799863/
- Teo M, World Neurosurg 2016;93:398. https://pubmed.ncbi.nlm.nih.gov/27368508/
- Thakur JD, Neurosurg Focus 2012;33:E12. https://pubmed.ncbi.nlm.nih.gov/22937846/
Carried over from the 09-27 review (verified 2026-09-27):
- Paldor I, J Clin Neurosci 2016;32:1. https://pubmed.ncbi.nlm.nih.gov/27450283/
- Grigoryan GY, Zh Vopr Neirokhir 2021;85:29. https://pubmed.ncbi.nlm.nih.gov/34156205/
- Pikis S, J Neurosurg 2023;138:405. https://pubmed.ncbi.nlm.nih.gov/36303474/
- Hayhurst C, Neuro Oncol 2012;14:87. https://pubmed.ncbi.nlm.nih.gov/22028389/
- Sughrue ME, Br J Neurosurg 2010;24:666. https://pubmed.ncbi.nlm.nih.gov/21070151/
- Neff BA, J Neurosurg 2017;127:992. https://pubmed.ncbi.nlm.nih.gov/28084915/
- Koos WT, J Neurosurg 1998;88:506. https://pubmed.ncbi.nlm.nih.gov/9488305/
14. Questions for Tuesday’s radiosurgery consult
Bring the disc. The team will want to load the images themselves.
Growth
- The official report measures the tumor at 33 × 28 × 28 mm. I was told about 2.2 cm before, and my own measurement of the December 2025 images, done the same way, is about 25 × 19 × 20 mm. Do you agree it has grown by about a centimetre in ten months?
- What explains growth this fast? Is this cystic change, bleeding inside the tumor, or something else? Does the pace change how sure you are of the diagnosis?
- How soon does this need treating? Is there any reason to wait, and is there a reason not to?
Size and whether Gamma Knife still fits
- Is this tumor still suitable for Gamma Knife at your center? What are your limits on size and on brainstem compression? – Background: the European guideline says that for large tumors compressing the brainstem, surgical decompression is the primary treatment, with radiosurgery as a possible follow-on (Goldbrunner 2020). – Gamma Knife has been used for 3 to 4 cm tumors: control was 82% at two years, 5% needed a shunt for hydrocephalus, and 3% needed surgery within six months (Yang 2011).
- If you would not treat it in one session, would you offer treatment in several sessions? One series of tumors over 3 cm reported 80% control, with 20% needing further treatment (Teo 2016).
- Would you recommend surgery first, possibly a planned partial removal with radiosurgery for what is left? Would you discuss my case with Dr. Altshuler at UofM, or at a tumor board?
- Tumors often swell for a time after radiosurgery (Hayhurst 2012; Pikis 2023 reported early expansion in 11% of Koos IV tumors). What happens if mine swells when it already presses on the brainstem?
Fluid spaces
- The official report says there is no hydrocephalus. My own comparison suggests the ventricles hold more fluid than in December. Can you compare the two scans, and does the change matter? Does it affect the choice between radiosurgery and surgery?
- Which symptoms should make me call you the same day, and which should send me to an emergency department?
Trigeminal nerve and numbness
- Does the tumor press on my trigeminal nerve, and can you see where the nerve enters the brainstem? Is the numbness from the nerve, from pressure on the brainstem, or both?
- With your approach, how likely is the numbness to improve, stay the same or get worse? After surgery it improved in about half of patients in one series (Neff 2017); results after radiosurgery vary widely.
- What dose would the trigeminal nerve and the brainstem receive, and what limits do you use?
Facial nerve, hearing and the lower nerves
- At this size, what is my risk of facial weakness with your approach? After surgery, facial function was normal or near-normal in about 67% for tumors over 20 mm, against 90% for smaller ones (Sughrue 2010).
- The bottom of the tumor now sits lower. Are the nerves for swallowing and voice at risk?
- The right inner-ear fluid looks dimmer than the left. Does that affect a later cochlear implant on that side?
Before you leave
- Ask for a formal comparison of October 2026 with December 2025 and September 2025 (the official report had none), the official Koos grade, and a copy of the December 2025 written report if they can get it.
- Ask who is coordinating your care between this office and UofM, and what the next step is this week.
Ideas and discussion
Have a lead, a study, a contact or a thought on any of this? Add it below. Comments appear once John approves them; your email is never shown.
Leave a Reply